Call us Toll Fee at: 877-206-5021    

 

 

 

 

 

 

KC-8  KC-12  KC-14 Vacuum Relay specifications

 

 

 

 

Item

Unit

Value

Voltage (Peak), Test Max., Contacts & to Base (15 A Leakage  Max., dc or 60Hz) ★

kV

17

Voltage (Peak), Operating Max. Contacts & to Base (15 A  Leakage Max.)

 

 

      dc or 60 Hz ★

kV

15

      2.5 MHz ★

kV

12

      16 MHz ★

kV

9

      32 MHz ★

kV

7

Current, Continuous Carry Max (RMS)

 

 

      dc or 60 Hz ★

Amps

50

      2.5 MHz ★

Amps

30

      16 MHz ★

Amps

17.5

      32 MHz ★

Amps

10

Resistance, Contact Max  1A, 28 Vdc ★

Ω

0.012

Rated Coil Voltage ★

V.DC

12

13.5

24

26.5

115

DC Coil Resistance

10%

72.5

83

180

270

3000

Coil Hi-Pot (V RMS, 60 Hz)

V

500

Capacitance

 

 

Across Open Contacts

pF

0.5

Contacts to Ground

pF

1

Operate Time

ms

15

Release Time

ms

9

Bounce MAX

ms

2

Pull-in Voltage  25℃ 26.5 Vdc Coil

V

9

10

15

16

70

Dropout Voltage  -55 to 125℃ 26.5 Vdc Coil

V

0.8-4

0.8-4.5

1.4-6.5

1.5-7

3-30

Mechanical life ★

Operation

1 million

Vibration, Operating, Sine (55-500 Hz  Peak)

G's

10

 Shock, Operating, 1/2 Sine11ms (Peak)

G's

50

Maximum Weight

g

86

 

 

 

 
 
 
 